trabecular metal acetabular

Sales Inquiry

  • Do Trabecular Metal Acetabular Components Reduce the Risk .

    Background A single-center study of 144 THAs revised specifically for periprosthetic joint infection (PJI) observed that trabecular metal (TM) acetabular components had a reduced risk of rerevision for subsequent infection compared with non-TM implants. It was suggested that TM was protective against infection after revision and that TM may be useful when revising THAs for PJI.

  • Trabecular Metal™ Modular Acetabular System

    Combining the Trilogy ® Acetabular System design with the proven benefits and biologic in-growth potential of Trabecular Metal Material presents a unique option for total hip arthroplasty. Trabecular Metal Shell configurations include Non-holed, Cluster-holed, and Multi-holed. These shells can be used with any of the Trilogy Acetabular Liners.

  • (PDF) Hedrocel trabecular metal monoblock acetabular cups .

    The study group consisted of 20 patients (21 hips) who underwent a revision hip arthroplasty using Trabecular Metal acetabular revision system. The follow-up period was between 7 .

  • Trabecular Metal™ Acetabular Revision System Buttress and .

    2 Trabecular Metal™ Acetabular Revision System Buttress and Shim Augments A Viable Alternative To Structural Allograft he Straight Buttress and Column • •T Buttress Augments provide superior structural support to the Trabecular Metal Revision Shell as an alternative to preparing and using structural

  • Trabecular metal acetabular components in primary total .

    Trabecular metal (ZimmerBiomet, Warsaw, IN, USA) is made of porous tantalum and has been shown to provide higher porosity, increased initial stability, and good bone ingrowth qualities (Bobyn et al. 1999, Beckmann et al. 2014). These advantages make it an attractive option in both primary and revision THA. While TM acetabular components are most

  • Zimmer Continuum Acetabular System

    2 Zimmer® Continuum® Acetabular System Surgical Technique Device Description • The Continuum Shell is hemispherical in shape with an exterior of ™Trabecular Metal Material ®that is bonded to a Tivanium alloy substrate. The Shell has a snap fit locking groove for acceptance of the Longevity® Highly Crosslinked Polyethylene Neutral or Elevated Liners.

  • Trabecular metal shell for type III acetabular defect .

    Nov 14, 2013 · Trabecular metal cups provide an excellent alternative to overcome severe acetabular bone defects. In this case scenario a trabecular metal shell was used, then a cemented captive PE cup was .

  • Trabecular Metal™ Acetabular Restrictor and Augment .

    Trabecular Metal Acetabular Restrictor and Augment Intra-operatively, carefully assess any acetabular bone defects present. Note the location, extent, and type of bone defect. It is equally important to assess the quality and location of the host bone that remains for

  • Trabecular Metal™ Cups for Acetabular . - SpringerLink

    Mar 10, 2009 · Acetabular component revision in the context of large contained bone defects with less than 50% host bone contact traditionally have been treated with roof reinforcement or antiprotrusio cages. Trabecular Metal™ cups (Zimmer, Inc, Warsaw, IN) may offer a reasonable treatment alternative. We evaluated the clinical and radiographic outcome of this mode of .

  • Trabecular Metal™ Acetabular Revision System

    The Zimmer® Trabecular Metal Acetabular Revision System sets new standards in the way surgeons perform revision surgery. It combines Trabecular Metal Technology with the ability to tailor individualized solutions for each patient—a combination no other competitive system offers.. The Trabecular Metal Buttress:. Is made entirely of Trabecular Metal Material—no substrate

  • Trabecular metal acetabular components in primary total .

    Trabecular metal (ZimmerBiomet, Warsaw, IN, USA) is made of porous tantalum and has been shown to provide higher porosity, increased initial stability, and good bone ingrowth qualities (Bobyn et al. 1999, Beckmann et al. 2014). These advantages make it an attractive option in both primary and revision THA. While TM acetabular components are most

  • Hip Replacement Products - Zimmer

    Zimmer Acetabular Systems give orthopedic surgeons the ability to address variations in anatomy and choose the bearing technology that best meets the needs of each patient. We also offer products that feature the proven benefits of Zimmer ® Trabecular Metal ™ Technology.

  • Hip Replacement Products - Zimmer

    Zimmer Acetabular Systems give orthopedic surgeons the ability to address variations in anatomy and choose the bearing technology that best meets the needs of each patient. We also offer products that feature the proven benefits of Zimmer ® Trabecular Metal ™ Technology.

  • Trabecular metal acetabular components show high .

    Further results from a study on trabecular metal acetabular components used in hip revision surgery suggest the use of these porous tantalum implants may lead to .

  • Trabecular Metal™ Acetabular Revision System

    The Zimmer® Trabecular Metal Acetabular Revision System sets new standards in the way surgeons perform revision surgery. It combines Trabecular Metal Technology with the ability to tailor individualized solutions for each patient—a combination no other competitive system offers.. The Trabecular Metal Buttress:. Is made entirely of Trabecular Metal Material—no substrate

  • Trabecular Metal™ Acetabular Revision System

    The Zimmer® Trabecular Metal Acetabular Revision System sets new standards in the way surgeons perform revision surgery. It combines Trabecular Metal Technology with the ability to tailor individualized solutions for each patient—a combination no other competitive system offers.. The Trabecular Metal Buttress:. Is made entirely of Trabecular Metal Material—no substrate

  • Trabecular Metal Used for Major Bone Loss in Acetabular .

    Trabecular Metal Used for Major Bone Loss in Acetabular Hip Revision. . The inherent properties of trabecular metal (TM) implants allow for many potential benefits in revision arthroplasty. . W.G. PaproskyAcetabular revision using a trabecular metal acetabular component for severe acetabular bone loss associated with a pelvic discontinuity.

  • Treatment of acetabular defects with the trabecular metal .

    Purpose: This review focuses on the use of cementless implants for acetabular revision. The use of trabecular metal cups, augments, jumbo cups, .

  • Trabecular Metal Technology

    Trabecular Metal Revision Acetabular Cup Trabecular Metal Material provides structural support for bone ingrowth and remodeling in acetabular revision and reconstruction.13,14 The bone-like properties of Trabecular Metal Material help facilitate joint reconstruction and restoration of normal weight bearing. The high coefficient

  • Trabecular metal shell for type III acetabular defect .

    Nov 14, 2013 · Trabecular metal cups provide an excellent alternative to overcome severe acetabular bone defects. In this case scenario a trabecular metal shell was used, then a cemented captive PE cup was .

  • Trabecular Metal Acetabular Restrictor and Augment

    Trabecular Metal Acetabular Restrictor and Augment Intra-operatively, carefully assess any acetabular bone defects present. Note the location, extent, and type of bone defect. It is equally important to assess the quality and location of the host bone that remains for support of the acetabular .

  • The Use of a Trabecular Metal Acetabular Component and .

    The potential for biologic fixation with the use of a trabecular metal acetabular component and augment may also provide improved long-term outcomes, unlike the use of a cage, which is subjected to nonbiologic fixation and the potential for fatigue failure 13, 14. The material properties of trabecular metal are ideal for acetabular revision.

  • The Use of a Trabecular Metal Acetabular Component and .

    The potential for biologic fixation with the use of a trabecular metal acetabular component and augment may also provide improved long-term outcomes, unlike the use of a cage, which is subjected to nonbiologic fixation and the potential for fatigue failure 13, 14. The material properties of trabecular metal are ideal for acetabular revision.

  • Recall Issued for Zimmer Trabecular Metal Modular .

    Oct 16, 2015 · Washington, DC: A Class 2 Recall has been issued for Zimmer Trabecular Metal Modular Acetabular System, a modular acetabular cup system consisting of a shell with a preassembled locking ring, a .

  • Trabecular Metal™ Acetabular Revision System (TMARS .

    Trabecular Metal™ Acetabular Revision System (TMARS) Ordering Information .

  • Continuum® Acetabular System - Zimmer

    Zimmer® Continuum Acetabular System provides highly flexible solutions for orthopedic surgeons who treat a wide range of patients. The system combines the biologic ingrowth of Trabecular Metal™ Technology with Zimmer® advanced bearing options. With one of the most comprehensive systems, surgeons have the ability to address variations of .

  • Trabecular Metal Augments for Acetabular Revision a "How .

    Trabecular Metal Augments for Acetabular Revision a "How to"

  • Trabecular Metal Acetabular Revision System

    Trabecular Metal Acetabular Revision System include Trabecular Metal Modular Multi-hole Shells, Longevity® Highly Crosslinked Trabecular Metal Modular Multi-hole Shells • To create initial stability, Trabecular Metal Material combines an excellent coefficient of friction against bone and an elliptical shape5,6 • Industry-leading locking

  • Trabecular Metal Acetabular Revision System | Zimmer Biomet

    The Zimmer Biomet Trabecular Metal Acetabular Revision System (TMARS) combines clinically proven Trabecular Metal Technology 1–3 with the ability to tailor individualized solutions for each patient. From simple to complex revision arthroplasty, this combination sets new standards for acetabular .

  • Trabecular Metal Acetabular Revision System

    in challenging acetabular revisions. Trabecular Metal • Evidence supporting Trabecular Metal acetabular components is well-documented across more than 300 publications. • Trabecular Metal cups used in revision THA have shown to be 21% less likely to be re-revised due to infection and 11% less likely to be re-revised for any reason.11–13